Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mayo Clin Proc ; 97(11): 1994-2004, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36210202

RESUMO

OBJECTIVE: To overcome the limitations of commercially available insulin immunoassays which have variable detection of analog insulin and can lead to clinically discordant results and misdiagnosis in the workup of factitious hypoglycemia. PATIENTS AND METHODS: We performed analytical validation of a liquid chromatography high resolution accurate mass (LC-HRAM) immunoassay to detect insulin analogs. We completed clinical assessment using a large cohort of human serum samples from 78 unique individuals, and subsequently used the assay in the evaluation of eight individuals with high diagnostic suspicion for factitious hypoglycemia. RESULTS: The performance characteristics show that the LC-HRAM immunoassay can be applied to detect five commonly used synthetic insulin analogs (lispro, glulisine, aspart, glargine metabolite, and detemir) in human serum. Our clinical cases show that this assay could be used in the diagnosis of factitious hypoglycemia by identifying the analog insulin(s) in question. CONCLUSION: The LC-HRAM immunoassay reported here overcomes a gap in our diagnostic pathway for hypoglycemia. The results obtained from our studies suggest that this method is appropriate for use in clinical laboratories when factitious hypoglycemia is considered as a differential diagnosis.


Assuntos
Hipoglicemia , Insulina , Humanos , Insulina/efeitos adversos , Insulina/análise , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Imunoensaio/métodos , Hipoglicemiantes/efeitos adversos
2.
J Proteome Res ; 21(8): 2045-2054, 2022 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-35849720

RESUMO

Targeted mass spectrometry-based platforms have become a valuable tool for the sensitive and specific detection of protein biomarkers in clinical and research settings. Traditionally, developing a targeted assay for peptide quantification has involved manually preselecting several fragment ions and establishing a limit of detection (LOD) and a lower limit of quantitation (LLOQ) for confident detection of the target. Established thresholds such as LOD and LLOQ, however, inherently sacrifice sensitivity to afford specificity. Here, we demonstrate that machine learning can be applied to qualitative PRM assays to discriminate positive from negative samples more effectively than a traditional approach utilizing conventional methods. To demonstrate the utility of this method, we trained an ensemble machine learning model using 282 SARS-CoV-2 positive and 994 SARS-CoV-2 negative nasopharyngeal swabs (NP swab) analyzed using a targeted PRM method. This model was then validated using an independent set of 200 positive and 150 negative samples and achieved a sensitivity of 92% relative to results obtained by RT-PCR, which was superior to a traditional approach that resulted in 86.5% sensitivity when analyzing the same data. These results demonstrate that machine learning can be applied to qualitative PRM assays and results in superior performance relative to traditional methods.


Assuntos
COVID-19 , SARS-CoV-2 , Teste para COVID-19 , Humanos , Aprendizado de Máquina , Espectrometria de Massas/métodos , Sensibilidade e Especificidade
4.
Clin Proteomics ; 18(1): 25, 2021 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-34686148

RESUMO

SARS-CoV-2, a novel human coronavirus, has created a global disease burden infecting > 100 million humans in just over a year. RT-PCR is currently the predominant method of diagnosing this viral infection although a variety of tests to detect viral antigens have also been developed. In this study, we adopted a SISCAPA-based enrichment approach using anti-peptide antibodies generated against peptides from the nucleocapsid protein of SARS-CoV-2. We developed a targeted workflow in which nasopharyngeal swab samples were digested followed by enrichment of viral peptides using the anti-peptide antibodies and targeted parallel reaction monitoring (PRM) analysis using a high-resolution mass spectrometer. This workflow was applied to 41 RT-PCR-confirmed clinical SARS-CoV-2 positive nasopharyngeal swab samples and 30 negative samples. The workflow employed was highly specific as none of the target peptides were detected in negative samples. Further, the detected peptides showed a positive correlation with the viral loads as measured by RT-PCR Ct values. The SISCAPA-based platform described in the current study can serve as an alternative method for SARS-CoV-2 viral detection and can also be applied for detecting other microbial pathogens directly from clinical samples.

5.
Anal Chem ; 93(37): 12532-12540, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34490782

RESUMO

Mass spectrometry (MS) is widely used in science and industry. It allows accurate, specific, sensitive, and reproducible detection and quantification of a huge range of analytes. Across MS applications, quantification by MS has grown most dramatically, with >50 million experiments/year in the USA alone. However, quantification performance varies between instruments, compounds, different samples, and within- and across runs, necessitating normalization with analyte-similar internal standards (IS) and use of IS-corrected multipoint external calibration curves for each analyte, a complicated and resource-intensive approach, which is particularly ill-suited for multi-analyte measurements. We have developed an internal calibration method that utilizes the natural isotope distribution of an IS for a given analyte to provide internal multipoint calibration. Multiple isotope distribution calibrators for different targets in the same sample facilitate multiplex quantification, while the emerging random-access automated MS platforms should also greatly benefit from this approach. Finally, isotope distribution calibration allows mathematical correction for suboptimal experimental conditions. This might also enable quantification of hitherto difficult, or impossible to quantify, targets, if the distribution is adjusted in silico to mimic the analyte. The approach works well for high resolution, accurate mass MS for analytes with at least a modest-sized isotopic envelope. As shown herein, the approach can also be applied to lower molecular weight analytes, but the reduction in calibration points does reduce quantification performance.


Assuntos
Isótopos , Espectrometria de Massas em Tandem , Calibragem , Padrões de Referência
6.
EBioMedicine ; 69: 103465, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34229274

RESUMO

BACKGROUND: The COVID-19 pandemic caused by severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) has overwhelmed health systems worldwide and highlighted limitations of diagnostic testing. Several types of diagnostic tests including RT-PCR-based assays and antigen detection by lateral flow assays, each with their own strengths and weaknesses, have been developed and deployed in a short time. METHODS: Here, we describe an immunoaffinity purification approach followed a by high resolution mass spectrometry-based targeted qualitative assay capable of detecting SARS-CoV-2 viral antigen from nasopharyngeal swab samples. Based on our discovery experiments using purified virus, recombinant viral protein and nasopharyngeal swab samples from COVID-19 positive patients, nucleocapsid protein was selected as a target antigen. We then developed an automated antibody capture-based workflow coupled to targeted high-field asymmetric waveform ion mobility spectrometry (FAIMS) - parallel reaction monitoring (PRM) assay on an Orbitrap Exploris 480 mass spectrometer. An ensemble machine learning-based model for determining COVID-19 positive samples was developed using fragment ion intensities from the PRM data. FINDINGS: The optimized targeted assay, which was used to analyze 88 positive and 88 negative nasopharyngeal swab samples for validation, resulted in 98% (95% CI = 0.922-0.997) (86/88) sensitivity and 100% (95% CI = 0.958-1.000) (88/88) specificity using RT-PCR-based molecular testing as the reference method. INTERPRETATION: Our results demonstrate that direct detection of infectious agents from clinical samples by tandem mass spectrometry-based assays have potential to be deployed as diagnostic assays in clinical laboratories, which has hitherto been limited to analysis of pure microbial cultures. FUNDING: This study was supported by DBT/Wellcome Trust India Alliance Margdarshi Fellowship grant IA/M/15/1/502023 awarded to AP and the generosity of Eric and Wendy Schmidt.


Assuntos
Teste Sorológico para COVID-19/métodos , Imunoensaio/métodos , Espectrometria de Massas/métodos , Animais , Antígenos Virais/química , Antígenos Virais/imunologia , Automação Laboratorial/métodos , Automação Laboratorial/normas , Teste Sorológico para COVID-19/normas , Chlorocebus aethiops , Proteínas do Nucleocapsídeo de Coronavírus/química , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Humanos , Imunoensaio/normas , Aprendizado de Máquina , Espectrometria de Massas/normas , Fosfoproteínas/química , Fosfoproteínas/imunologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...